Condo Inspection: Chicago, IL 60641 - August 5, 2026

A condo inspection of a unit in Chicago's Klee Building on Milwaukee Ave documented 21 findings, including 4 safety hazards - a missing range anti-tip bracket, improper dryer venting, and a missing light cover.

Chicago, 60641 · Aug 5, 2026
Condo Inspection: Chicago, IL 60641 - August 5, 2026

This condo inspection covered a unit in Chicago's historic Klee Building on Milwaukee Ave. Of the 48 components inspected, our team documented 21 total findings: 9 recommendations, 8 maintenance items, and 4 safety hazards. The range was missing its anti-tip bracket, improper dryer vent material was found, a connected light fixture was missing its cover, and smoke/CO detectors were missing or over 10 years old. Other findings included a failed double-pane window, a leaking dishwasher, a loose toilet, and a missing washer pan.

Kitchen Components and Appliances

The range/stove was missing its anti-tip bracket - a safety hazard, since without it a loaded oven door can cause the appliance to tip forward. The range hood/microwave exhaust fan was missing its filter, the microwave was found to be of re-circulating type (unvented), and the dishwasher was leaking.

Interiors

A window showed a failed double-pane seal (condensation trapped between the glass layers). An exterior door's latch mechanism had failed, louvered doors were rubbing on an appliance, and door locks were non-functioning for bedroom and bathroom. Ceiling and wall/trim cosmetics were noted, cabinet damage was found, and floors showed moderate wear.

Bathroom

A toilet was loose.

Plumbing

A washer pan was missing - worth installing, since its job is to catch minor leaks and route them safely away. Improper dryer vent material was identified - a safety hazard, since certain vent materials are more prone to sagging, trapping lint, and posing a fire risk compared to rigid or semi-rigid metal venting.

Heating

The furnace is on the older side.

Air Conditioning

The cooling equipment is due for regular maintenance; it was tested and operated during the inspection.

Electrical

A connected light fixture on the balcony was found missing its cover - a safety hazard, since an uncovered fixture leaves live components and the bulb itself more exposed than intended. Smoke and carbon monoxide detectors that were missing or over 10 years old were also flagged as a safety hazard, worth correcting before move-in since working detectors are a basic life-safety requirement. Less urgently, the panel needed cleaning.

Findings Summary

Microwave: Exhaust Fan Missing Filter
Doors: Non-Functioning Door Locks
Floors: Moderate Wear
Walls & Trim: Cosmetics
Heating Equipment: Old Furnace
HVAC: Regular Maintenance / Tune Up
Dishwasher: Dishwasher Leak
Windows: Failed Double-Pane Window (Condensation)
Doors: Louvered Doors Rubbing on Appliance
Countertops & Cabinets: Cabinet Damage
Plumbing & Fixtures: Loose Toilet
Washer: Missing Washer Pan
Range/Stove/Oven: Anti-Tip Bracket Missing
Dryer: Improper Dryer Vent Material
Smoke & Carbon Monoxide: Missing / Over 10 Years
condo inspection chicago portage park condo inspection dryer vent safety missing smoke detectors home inspector chicago il missing light fixture cover belmont cragin condo range anti-tip bracket chicago condo inspector
26 Views 0 Likes 1 Shares
Share this article:
Chicago certified inspector
Roof inspector Chicago
Attic insulation inspector
Residential property inspector
New construction inspector
Multi-unit inspector
Chimney inspector
Plumbing inspector
Exterior inspector
Deck inspector

Book Your Home Inspection Now!

Serving the Chicago Metropolitan Area

Monday - Saturday 8:00 AM - 6:00 PM

1
What & Where
2
Who
3
When
4
Review

What & Where

Please select a service.
Please select an address from the suggestions or enter it manually below.
Please complete all required address fields.

Who to Contact

Client
First name is required.
Last name is required.
A valid email address is required.
Phone number is required.
You must agree to SMS communications to proceed.
Client #2 Remove

Agent (Optional)

When

Select a day, then choose a time. Picking a time slot will take you to the next step.

Can't find the right time? Call us at (312) 889-3365 or email support@getapro.io.

Review & Schedule

Inspection Service
Address
Date & Time
Client
Price
Please tell us how you heard about us.